{"id":90966,"date":"2026-10-24T11:04:12","date_gmt":"2026-10-24T03:04:12","guid":{"rendered":"https:\/\/www.konmison.com\/?p=90966"},"modified":"2026-10-24T11:04:12","modified_gmt":"2026-10-24T03:04:12","slug":"how-to-read-beauty-machine-specification-sheet","status":"publish","type":"post","link":"https:\/\/www.konmison.com\/ja\/how-to-read-beauty-machine-specification-sheet\/","title":{"rendered":"How to Read a Beauty Machine Specification Sheet"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Why a specification sheet needs a second read<\/h2>\n\n\n\n<p>A specification sheet is useful only when a buyer can connect each field to a purchasing, training, service, or shipping decision. A long list of numbers can look technical while still leaving important questions unanswered. Is the stated power input or output? Does the handle count include every applicator, or only the main treatment handpieces? Is a frequency fixed, adjustable, or simply part of the product name? Which dimensions describe the cabinet, and which describe the shipping package?<\/p>\n\n\n\n<p>For a clinic, these details affect room planning, operator training, daily checks, and replacement planning. For a distributor or OEM buyer, they affect quotation accuracy, product comparison, customer documentation, and after-sales support. The goal is not to find the largest number. The goal is to understand what the number measures, which configuration it belongs to, and what evidence the supplier can provide.<\/p>\n\n\n\n<p>Start by recording the exact model, configuration, language, and revision date shown on the sheet. Keep that record with the quotation and the customer handover file. If a field is missing, ask the supplier rather than filling it with a value from a similar machine.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">1. Electrical and operating data<\/h2>\n\n\n\n<p>Electrical fields are the first place where two otherwise similar machines can become difficult to compare. A sheet may show input voltage, frequency, rated power, maximum power, fuse information, or a regional plug option. These are not interchangeable fields.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Separate input voltage from power<\/h3>\n\n\n\n<p>Ask whether the voltage is a fixed regional version or a selectable range. Confirm the frequency requirement and plug arrangement for the destination market. Then ask whether the wattage is rated input power, maximum input power, or a value measured under a particular operating mode. A buyer preparing a quotation should keep those labels exactly as supplied.<\/p>\n\n\n\n<p>The hydrodermabrasion category page describes multi-function machines using water, oxygen, hot bubbles, adjustable vacuum suction, and several handle configurations. That public page is useful for understanding the category, but it does not make every electrical value universal across every listing. Use the <a href=\"https:\/\/www.konmison.com\/ja\/%e7%be%8e%e5%ae%b9%e6%a9%9f%e5%99%a8\/%e7%be%8e%e9%a1%94%e5%99%a8\/%e3%83%8f%e3%82%a4%e3%83%89%e3%83%ad%e3%83%80%e3%83%bc%e3%83%9e%e3%83%96%e3%83%ac%e3%83%bc%e3%82%b7%e3%83%a7%e3%83%b3%e3%83%9e%e3%82%b7%e3%83%b3\/\">hydrodermabrasion machine category<\/a> as a starting point, then confirm the exact model&#8217;s sheet before publishing a product comparison.<\/p>\n\n\n\n<p>For an OEM order, request the following in writing:<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>input voltage and permitted tolerance;<\/li><li>operating frequency;<\/li><li>rated and maximum input power, with the test condition;<\/li><li>plug type and cable length, if relevant;<\/li><li>fuse or circuit recommendation when the supplier provides it;<\/li><li>whether the values change with optional handles, pumps, cooling parts, or a different cabinet.<\/li><\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Turn electrical data into a handover check<\/h3>\n\n\n\n<p>The clinic administrator should record the site voltage before installation and check that the delivered nameplate matches the approved quotation. The distributor should keep a photo of the nameplate with the serial or batch record. If the machine is moved to another region, the new operator should not assume that a similar-looking cabinet has the same electrical configuration.<\/p>\n\n\n\n<p>If the specification sheet gives only a broad voltage phrase, use &#8220;ask the supplier to confirm the destination configuration&#8221; in the customer file. That is more useful than inserting a guessed value.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">2. Handpiece and applicator details<\/h2>\n\n\n\n<p>The word &#8220;handle&#8221; can hide several different facts. A machine may have treatment handpieces, rollers, probes, bottles, tips, or interchangeable connectors. Count alone does not tell a buyer what the operator can do or what the service team must stock.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Build a handle register<\/h3>\n\n\n\n<p>Create one row for each supplied handpiece or applicator. Record its name, visible function, connector, compatible consumable, cleaning method, storage method, and whether it is standard or optional. If the page lists a tip family but not a model-specific compatibility table, ask the supplier for that table.<\/p>\n\n\n\n<p>Hydrodermabrasion pages commonly describe water and oxygen paths, vacuum-assisted tips, hot-bubble functions, and other facial-care handles. Do not combine those public category descriptions with a different model&#8217;s exact handle count. A 14-handle listing and a smaller desktop listing are separate configurations. The safe comparison is model by model.<\/p>\n\n\n\n<p>The same rule applies to cavitation machines. The <a href=\"https:\/\/www.konmison.com\/ja\/%e7%be%8e%e5%ae%b9%e6%a9%9f%e5%99%a8\/%e3%82%b9%e3%83%aa%e3%83%9f%e3%83%b3%e3%82%b0%e3%83%9e%e3%82%b7%e3%83%b3\/%e3%82%ad%e3%83%a3%e3%83%93%e3%83%86%e3%83%bc%e3%82%b7%e3%83%a7%e3%83%b3%e3%83%9e%e3%82%b7%e3%83%b3\/\">cavitation machine category<\/a> shows that configurations may combine cavitation, RF, vacuum, rollers, or other handles. A buyer should ask whether each named function has its own handle, shares a connector, or is included only in an optional package. The same model-by-model check applies to facial platforms: the <a href=\"https:\/\/www.konmison.com\/ja\/%e7%be%8e%e5%ae%b9%e6%a9%9f%e5%99%a8\/%e7%be%8e%e9%a1%94%e5%99%a8\/%e3%83%8f%e3%82%a4%e3%83%89%e3%83%a9%e3%83%95%e3%82%a7%e3%82%a4%e3%82%b7%e3%83%a3%e3%83%ab%e3%83%9e%e3%82%b7%e3%83%b3\/\">hydrafacial machine category<\/a> lists the current hydrafacial configurations, and each listing should be confirmed against its own sheet before a quotation.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Ask what the operator must learn<\/h3>\n\n\n\n<p>For each handle, write one training sentence: &#8220;Use this handle for ___, connect it to ___, check ___ before use, and clean\/store it by ___.&#8221; If the supplier cannot complete the sentence from the manual or configuration sheet, the handover is not ready.<\/p>\n\n\n\n<p>For distributors, this register becomes a customer-ready packing checklist. It also helps separate a missing accessory from an operator setup question during remote support. Keep the supplied handle list with the machine ID, and update it when an approved replacement is sent.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">3. Output ranges and operating controls<\/h2>\n\n\n\n<p>Output fields are often the most misunderstood part of a specification sheet. Frequency, energy, intensity, pulse, suction, flow, temperature, and time can be expressed in different units. The same word may also refer to a setting range rather than a measured output.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Read the unit before reading the number<\/h3>\n\n\n\n<p>Write down the field name, unit, minimum, maximum, and adjustment method. For example, ask whether a frequency is fixed or adjustable, whether an energy range is shown per area or per pulse, and whether a vacuum value is a setpoint or a measured result. Ask how the screen displays the setting and which values are restricted by the selected handle.<\/p>\n\n\n\n<p>The public cavitation comparison article shows why a product name alone is not enough: it contrasts 40,000 Hz and 80,000 Hz entries and separately discusses penetration depth, sensation, body areas, and session duration. Those values belong to that article&#8217;s comparison context. They should not be copied into every cavitation machine quotation. The supplier should confirm the exact model, handle, and operating mode.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Make the control interface part of the specification<\/h3>\n\n\n\n<p>A buyer should ask for screenshots or a short operating description covering:<\/p>\n\n\n\n<ol class=\"wp-block-list\"><li>the home screen and model language;<\/li><li>the selected handle or function indicator;<\/li><li>the adjustable fields and their units;<\/li><li>prompts shown during setup;<\/li><li>what happens when a value is outside the allowed range;<\/li><li>whether the interface changes when an optional handle is connected.<\/li><\/ol>\n\n\n\n<p>This is valuable for distributors because training materials can mirror the actual screen. It also reduces support messages that describe a value without its unit or operating mode.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Do not treat a range as a promise<\/h3>\n\n\n\n<p>An output range is a configuration reference, not a guaranteed result for every customer or every procedure. In a quotation, state the exact model and configuration beside the range. In a training file, explain who may adjust the field, what the approved starting point is, and which conditions require supplier review.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">4. Dimensions, weight, and shipping fields<\/h2>\n\n\n\n<p>Cabinet dimensions are not the same as packed dimensions. Net weight is not gross shipping weight. A machine that fits through a clinic door may still need a different route once the wooden case, pallet, or lift-gate requirement is included.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Request both operating and shipping measurements<\/h3>\n\n\n\n<p>Ask the supplier for:<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>assembled width, depth, and height;<\/li><li>working footprint with the screen or handle holder in its normal position;<\/li><li>net machine weight;<\/li><li>packed dimensions and gross weight;<\/li><li>case or pallet details;<\/li><li>number of cartons;<\/li><li>lifting points or handling instructions;<\/li><li>whether optional handles change the package size.<\/li><\/ul>\n\n\n\n<p>Record the measurement source and revision date. If the supplier provides only assembled dimensions, mark packed dimensions as &#8220;ask the supplier.&#8221; Do not estimate freight size from a photograph.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Match measurements to the customer&#8217;s workflow<\/h3>\n\n\n\n<p>The clinic should measure the doorway, lift, treatment room, operator clearance, and storage area. The distributor should add a delivery checklist that confirms carton count, visible damage, serial or batch information, and included handles. For an OEM buyer, packaging artwork and carton labels should be treated as separate confirmation items rather than assumed from the machine body.<\/p>\n\n\n\n<p>The product category pages can show broad machine families and configuration examples, but the exact shipping fields remain model-specific. This is one reason a quotation should attach the chosen configuration sheet instead of relying on a category-page description.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">5. A buyer comparison table<\/h2>\n\n\n\n<p>Use the following table when comparing two supplier sheets. The final value should come from the exact model and configuration.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Field to compare<\/th><th>What to record<\/th><th>Why it matters<\/th><th>If the sheet is unclear<\/th><\/tr><\/thead><tbody><tr><td>Model and revision<\/td><td>Full model, configuration, revision date<\/td><td>Prevents mixed specifications<\/td><td>Ask for the current approved sheet<\/td><\/tr><tr><td>\u5165\u529b\u96fb\u5727<\/td><td>Voltage, frequency, plug version<\/td><td>Confirms site compatibility<\/td><td>Ask for destination-specific confirmation<\/td><\/tr><tr><td>\u30d1\u30ef\u30fc<\/td><td>Rated or maximum input, test condition<\/td><td>Supports electrical planning<\/td><td>Ask which power definition is used<\/td><\/tr><tr><td>\u30cf\u30f3\u30c9\u30eb<\/td><td>Name, count, connector, optional status<\/td><td>Drives training and spare planning<\/td><td>Ask for a handle register<\/td><\/tr><tr><td>Output fields<\/td><td>Unit, range, adjustment, mode<\/td><td>Makes comparisons meaningful<\/td><td>Ask for a screen or manual excerpt<\/td><\/tr><tr><td>Dimensions<\/td><td>Working and packed dimensions<\/td><td>Supports room and freight planning<\/td><td>Ask for gross weight and carton data<\/td><\/tr><tr><td>\u6d88\u8017\u54c1<\/td><td>Type, compatibility, storage<\/td><td>Prevents unsuitable replenishment<\/td><td>Ask which item reference is approved<\/td><\/tr><tr><td>\u30a4\u30f3\u30bf\u30fc\u30d5\u30a7\u30fc\u30b9<\/td><td>Language, prompts, selected function<\/td><td>Improves handover and support<\/td><td>Ask for interface screenshots<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>This table is also suitable for a distributor&#8217;s quotation review. Add a &#8220;source&#8221; column and link every value to the supplier page, sheet, photo, or written confirmation.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">6. Questions to ask before an OEM quotation<\/h2>\n\n\n\n<p>OEM buyers should send a structured question list. It saves time because the supplier can answer configuration questions together instead of correcting a quotation later.<\/p>\n\n\n\n<p>Ask the supplier to confirm the exact model and whether the quoted configuration is standard, optional, or customized. Request the electrical version, plug, interface language, cabinet color, logo placement, packaging label, and included handpieces. Ask which fields change when a handle, pump, cooling part, or software language is changed.<\/p>\n\n\n\n<p>Ask for the training and after-sales handover scope. Which user actions are covered in the manual? Which cleaning points are shown? Which consumables are approved? What information should a distributor collect before requesting service? The <a href=\"https:\/\/www.konmison.com\/ja\/hydrodermabrasion-machine-troubleshooting-guide\/\">hydrodermabrasion machine troubleshooting guide<\/a> is a useful internal reference for the kind of model, handle, consumable, symptom, and screen information that a support team may need to collect.<\/p>\n\n\n\n<p>Ask for shipping documentation that matches the final configuration: carton count, packed dimensions, gross weight, label format, and handling notes. Ask the supplier to identify any field that is still pending rather than filling it with a value from a similar machine.<\/p>\n\n\n\n<p>For a broader maintenance handover, the <a href=\"https:\/\/www.konmison.com\/ja\/beauty-machine-maintenance-schedule\/\">beauty machine maintenance schedule<\/a> can help the distributor structure daily, weekly, monthly, and quarterly records. Keep the specification sheet and maintenance SOP together so that the operator knows which checks belong to that exact model.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">7. A practical approval workflow<\/h2>\n\n\n\n<p>Use a five-stage approval workflow before the specification is shared with a customer.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Stage 1: Lock the model identity<\/h3>\n\n\n\n<p>Record the model, configuration, page or document revision, and intended destination. Do not compare a base model with a customized listing under one row.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Stage 2: Mark every field as verified or pending<\/h3>\n\n\n\n<p>Use &#8220;verified&#8221; only when the value appears on the exact sheet or in a written supplier confirmation. Use &#8220;ask the supplier&#8221; for missing voltage, power, dimensions, weight, handle compatibility, or output details.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Stage 3: Review training impact<\/h3>\n\n\n\n<p>Turn each handle, control, and cleaning point into a training line. Check whether the customer needs a diagram, translated interface, consumable list, or service form.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Stage 4: Review shipping impact<\/h3>\n\n\n\n<p>Check working footprint, packed size, gross weight, carton count, and site access. Keep shipping information separate from operating measurements.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Stage 5: Freeze the quotation attachment<\/h3>\n\n\n\n<p>Save the final sheet with a revision date and configuration name. The distributor should send the same revision to sales, training, warehouse, and after-sales staff. If a value changes, update the quotation attachment and customer handover record together.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Frequently asked questions<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Should I compare machines by the highest power number?<\/h3>\n\n\n\n<p>No. First confirm whether the number is rated input power, maximum input power, or another supplier-defined value. Compare the same field, unit, operating mode, and configuration. A clear lower value can be more useful than a larger unlabelled number because it supports electrical planning, training, and a consistent quotation.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">What should I do when the sheet does not list packed dimensions?<\/h3>\n\n\n\n<p>Mark packed dimensions and gross weight as pending, then ask the supplier for the final carton or pallet data for the selected configuration. Do not estimate from cabinet dimensions or a product photograph. Keep assembled measurements and shipping measurements in separate columns in the buyer&#8217;s comparison file.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">How can a distributor avoid mixing handpiece information?<\/h3>\n\n\n\n<p>Create a handle register tied to the exact machine ID and configuration. List each handle, connector, compatible consumable, cleaning point, and optional status. Give the same register to sales, warehouse, training, and after-sales teams. When a replacement is supplied, record the approved item reference and update the customer file.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Can a category page replace a model specification sheet?<\/h3>\n\n\n\n<p>No. A category page helps a buyer understand the product family and common functions. The model sheet must confirm the exact voltage, power, handle set, output fields, dimensions, weight, packaging, and interface. If the model sheet does not contain a value, ask the supplier before placing it in a quotation or training document.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">What should be attached to an OEM quotation?<\/h3>\n\n\n\n<p>Attach the exact configuration sheet, a marked list of pending fields, the handle register, electrical version, interface language, packaging details, and the requested handover documents. Add the revision date and model identity to every attachment so that later changes can be traced without confusing two configurations.<\/p>\n\n\n\n<script type=\"application\/ld+json\">{\n    \"@context\": \"https:\\\/\\\/schema.org\",\n    \"@type\": \"FAQPage\",\n    \"mainEntity\": [\n        {\n            \"@type\": \"Question\",\n            \"name\": \"Should I compare machines by the highest power number?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"No. First confirm whether the number is rated input power, maximum input power, or another supplier-defined value. Compare the same field, unit, operating mode, and configuration. A clear lower value can be more useful than a larger unlabelled number because it supports electrical planning, training, and a consistent quotation.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What should I do when the sheet does not list packed dimensions?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Mark packed dimensions and gross weight as pending, then ask the supplier for the final carton or pallet data for the selected configuration. Do not estimate from cabinet dimensions or a product photograph. Keep assembled measurements and shipping measurements in separate columns in the buyer\\u2019s comparison file.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"How can a distributor avoid mixing handpiece information?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Create a handle register tied to the exact machine ID and configuration. List each handle, connector, compatible consumable, cleaning point, and optional status. Give the same register to sales, warehouse, training, and after-sales teams. When a replacement is supplied, record the approved item reference and update the customer file.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"Can a category page replace a model specification sheet?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"No. A category page helps a buyer understand the product family and common functions. The model sheet must confirm the exact voltage, power, handle set, output fields, dimensions, weight, packaging, and interface. If the model sheet does not contain a value, ask the supplier before placing it in a quotation or training document.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What should be attached to an OEM quotation?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Attach the exact configuration sheet, a marked list of pending fields, the handle register, electrical version, interface language, packaging details, and the requested handover documents. Add the revision date and model identity to every attachment so that later changes can be traced without confusing two configurations.\"\n            }\n        }\n    ]\n}<\/script>","protected":false},"excerpt":{"rendered":"<p>Why a specification sheet needs a second read A specification sheet is useful only when a buyer can connect each field to a purchasing, training, service, or shipping decision. A long list of numbers can look technical while still leaving important questions unanswered. Is the stated power input or output? Does the handle count include every applicator, or only the main treatment handpieces? Is a frequency fixed, adjustable, or simply part of the product name? Which dimensions describe the cabinet, and which describe the shipping package? For a clinic, these details affect room planning, operator training, daily checks, and replacement planning. For a distributor or OEM buyer, they affect quotation [&hellip;]<\/p>","protected":false},"author":3,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_seopress_robots_primary_cat":"","_seopress_titles_title":"How to Read a Beauty Machine Spec Sheet","_seopress_titles_desc":"A practical B2B guide to reading machine voltage, power, handpieces, output ranges, dimensions, shipping fields, and OEM questions for clinic buyers.","_seopress_robots_index":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-90966","post","type-post","status-publish","format-standard","hentry","category-news"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.konmison.com\/ja\/wp-json\/wp\/v2\/posts\/90966","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.konmison.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.konmison.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.konmison.com\/ja\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.konmison.com\/ja\/wp-json\/wp\/v2\/comments?post=90966"}],"version-history":[{"count":1,"href":"https:\/\/www.konmison.com\/ja\/wp-json\/wp\/v2\/posts\/90966\/revisions"}],"predecessor-version":[{"id":90967,"href":"https:\/\/www.konmison.com\/ja\/wp-json\/wp\/v2\/posts\/90966\/revisions\/90967"}],"wp:attachment":[{"href":"https:\/\/www.konmison.com\/ja\/wp-json\/wp\/v2\/media?parent=90966"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.konmison.com\/ja\/wp-json\/wp\/v2\/categories?post=90966"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.konmison.com\/ja\/wp-json\/wp\/v2\/tags?post=90966"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}