{"id":90088,"date":"2026-09-23T10:46:43","date_gmt":"2026-09-23T02:46:43","guid":{"rendered":"https:\/\/www.konmison.com\/?p=90088"},"modified":"2026-09-23T10:46:44","modified_gmt":"2026-09-23T02:46:44","slug":"shockwave-therapy-machine-focused-vs-radial","status":"publish","type":"post","link":"https:\/\/www.konmison.com\/ru\/shockwave-therapy-machine-focused-vs-radial\/","title":{"rendered":"Shockwave Therapy Machine Buyer&#8217;s Guide: Focused vs Radial"},"content":{"rendered":"<p>A shockwave therapy machine makes an unusual promise to a clinic: no needle, no per-session consumable, no downtime, and a slot that runs ten to fifteen minutes. That is why so many salons, physiotherapy rooms and men&#8217;s wellness studios added one over the past three years \u2014 and why a good number bought the wrong one.<\/p>\n\n\n\n<p>The confusion is rarely about the brand. It comes down to one question two machines with near-identical marketing copy can answer in opposite ways: does the energy converge on a focal point, or spread out in a fan? That difference decides which clients you can accept, how deep you can work and how comfortable the session feels.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">01 What a Shockwave Therapy Machine Actually Does<\/h2>\n\n\n\n<p>Extracorporeal shockwave therapy (ESWT) delivers a short, high-pressure acoustic pulse into tissue from outside the body. The pulse crosses the skin, releases its energy at a target depth and is gone in microseconds. Nothing is injected and nothing is cut.<\/p>\n\n\n\n<p>Three abbreviations appear constantly in supplier documentation. <strong>ESWT<\/strong> is the general term for shockwave therapy applied from outside the body. <strong>F-ESWT<\/strong> is used by many manufacturers to specify the focused variant, where the wave converges on a defined point. <strong>ESWL<\/strong> is a different procedure \u2014 lithotripsy, where shockwaves break up stones.<\/p>\n\n\n\n<p>In practice the technology serves three client groups. The largest is musculoskeletal pain and soft-tissue recovery: shoulder, elbow, wrist, knee, plantar fascia, Achilles and lower back. The second is sports and post-training recovery, where the goal is muscle relaxation and circulation rather than rehabilitation. The third \u2014 smaller but growing quickly in private clinics \u2014 is men&#8217;s wellness, covered in section 07. It sits naturally beside the <strong><a href=\"https:\/\/www.konmison.com\/ru\/%d0%bb%d1%83%d1%87%d1%88%d0%b8%d0%b5-%d0%b2%d0%b8%d0%b1%d1%80%d0%b0%d1%86%d0%b8%d0%be%d0%bd%d0%bd%d1%8b%d0%b5-%d0%bc%d0%b0%d1%81%d1%81%d0%b0%d0%b6%d0%bd%d1%8b%d0%b5-%d0%bc%d0%b0%d1%88%d0%b8%d0%bd\/\">vibration massage machines<\/a><\/strong> many body-focused clinics already own: same client, same room.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">02 Focused vs Radial: The Two Energy Distribution Types<\/h2>\n\n\n\n<p>Every shockwave machine belongs to one of two families, and the family decides almost everything else.<\/p>\n\n\n\n<p>A <strong>radial<\/strong> wave (also called unfocused, or pneumatic) spreads outward from the applicator in a fan or umbrella shape. There is no defined focal point, peak energy sits at the skin surface and falls off quickly with depth \u2014 published figures put effective penetration at roughly 1.3 to 3.8 cm. Because the wave covers a wide area and needs no precise positioning, radial machines forgive an imprecise hand.<\/p>\n\n\n\n<p>A <strong>focused<\/strong> wave concentrates its energy onto a defined point some distance inside the tissue. Energy density at the focal spot is far higher than at the skin: the target receives a strong dose while the surface receives a weak one.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u041f\u0443\u043d\u043a\u0442<\/th><th>Radial (unfocused)<\/th><th>Focused<\/th><\/tr><\/thead><tbody><tr><td>Energy shape<\/td><td>Fan \/ umbrella, no defined focal point<\/td><td>Converges on a defined focal spot<\/td><\/tr><tr><td>Peak energy location<\/td><td>Skin surface<\/td><td>At the focal point, inside the tissue<\/td><\/tr><tr><td>Effective depth<\/td><td>Approx. 1.3 \u2013 3.8 cm<\/td><td>Deep; adjustable by applicator<\/td><\/tr><tr><td>Surface sensation<\/td><td>Higher \u2014 energy is concentrated at the skin<\/td><td>Lower \u2014 surface energy density is small<\/td><\/tr><tr><td>Positioning demand<\/td><td>Low; large areas covered quickly<\/td><td>Higher; the focal point must be aimed<\/td><\/tr><tr><td>Typical best fit<\/td><td>Superficial, wide-area soft tissue; muscle spasm; post-training relaxation<\/td><td>Small, deep or point lesions; chronic tendon attachments<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>If your list is dominated by broad, superficial muscle work, radial does the job at a lower entry point. If you intend to work on chronic tendon attachments, small deep lesions or men&#8217;s wellness protocols, the focal point is not a luxury \u2014 it is the mechanism you are selling.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/www.konmison.com\/wp-content\/uploads\/2026\/09\/focused-vs-radial-shockwave-energy-1200x675-1.png\" alt=\"Schematic cross-section comparing radial shockwave energy spreading in a fan near the skin versus focused energy converging at a point inside tissue\" class=\"wp-image-90091\" srcset=\"https:\/\/www.konmison.com\/wp-content\/uploads\/2026\/09\/focused-vs-radial-shockwave-energy-1200x675-1.png 1200w, https:\/\/www.konmison.com\/wp-content\/uploads\/2026\/09\/focused-vs-radial-shockwave-energy-1200x675-1-18x10.png 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">Schematic; tissue layers illustrative, not to scale.<\/figcaption><\/figure><\/div>\n\n\n<h2 class=\"wp-block-heading\">03 Pneumatic, Electromagnetic and Piezoelectric: Three Ways to Generate the Wave<\/h2>\n\n\n\n<p>Most buyer guides merge these two questions together; they are separate: <strong>how the wave is generated<\/strong>, \u0438 <strong>how the energy is distributed<\/strong>.<\/p>\n\n\n\n<p><strong>Pneumatic (ballistic).<\/strong> Compressed air drives a metal projectile inside the handpiece into the applicator head, producing a scattered mechanical wave. The design is simple, durable and cheap to maintain, which is why it dominates the entry tier. Because the wave is divergent, energy decays quickly with depth.<\/p>\n\n\n\n<p><strong>Electromagnetic.<\/strong> A high-voltage pulse creates a transient magnetic field that drives a metal membrane, compressing a liquid medium to generate the wave; an acoustic lens then focuses it. Output is stable, the focal point is controllable, running noise is low and no electrode needs replacing. This design sits behind many professional focused machines.<\/p>\n\n\n\n<p><strong>Piezoelectric.<\/strong> A water-filled applicator holds an array of piezoelectric ceramic elements. Under voltage the crystals deform in unison and generate the wave directly inside the water; the spherical geometry of the array focuses it, with no lens or reflector.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Generation method<\/th><th>Focal behaviour<\/th><th>Depth reach<\/th><th>\u0420\u0430\u0441\u0445\u043e\u0434\u043d\u044b\u0435 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u044b<\/th><th>Relative cost<\/th><\/tr><\/thead><tbody><tr><td>Pneumatic (ballistic)<\/td><td>Divergent, no true focus<\/td><td>Limited (approx. 1.3 \u2013 3.8 cm effective)<\/td><td>Projectile \/ applicator wear<\/td><td>Lowest<\/td><\/tr><tr><td>\u042d\u043b\u0435\u043a\u0442\u0440\u043e\u043c\u0430\u0433\u043d\u0438\u0442\u043d\u044b\u0439<\/td><td>Focused via acoustic lens<\/td><td>Deep, controllable<\/td><td>No electrode replacement needed<\/td><td>Mid to high<\/td><\/tr><tr><td>Piezoelectric<\/td><td>Self-focusing crystal array; smallest focal volume of the three<\/td><td>Deep; focal distance changed by swapping applicators<\/td><td>No electrode or membrane wear<\/td><td>Highest<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/www.konmison.com\/wp-content\/uploads\/2026\/09\/shockwave-generation-methods-compared-1200x675-1.png\" alt=\"Diagram comparing pneumatic, electromagnetic and piezoelectric shockwave generation methods\" class=\"wp-image-90092\" srcset=\"https:\/\/www.konmison.com\/wp-content\/uploads\/2026\/09\/shockwave-generation-methods-compared-1200x675-1.png 1200w, https:\/\/www.konmison.com\/wp-content\/uploads\/2026\/09\/shockwave-generation-methods-compared-1200x675-1-18x10.png 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">Generation method and energy distribution are separate buying questions.<\/figcaption><\/figure><\/div>\n\n\n<h2 class=\"wp-block-heading\">04 What a Piezoelectric Focused Source Changes for the Operator<\/h2>\n\n\n\n<p>Four consequences matter more than the spec sheet suggests.<\/p>\n\n\n\n<p><strong>The focal spot is very small.<\/strong> The focal volume of a piezoelectric array is a fine needle-shaped cone \u2014 the tightest of the three focused designs, with a focal distance of roughly 6 cm and focal deviation reported within about 1 mm. Energy is deposited at the target rather than spread along the path.<\/p>\n\n\n\n<p><strong>Surface sensation is lower.<\/strong> Because the applicator aperture is wide, energy density at the skin is low. Operators report that clients tolerate piezoelectric sessions with less discomfort than pneumatic or electrohydraulic alternatives, in many cases without analgesia. For a private clinic selling comfort alongside results, that is a commercial advantage as much as a clinical one. You can see how this is configured on the <strong><a href=\"https:\/\/www.konmison.com\/ru\/%d0%b0%d1%80%d1%82%d0%b8%d0%ba%d1%83%d0%bb-%d1%82%d0%be%d0%b2%d0%b0%d1%80%d0%b0\/piezoelectric-focused-shockwave-therapy-machine-for-pain-relief-ed-treatment\/\">piezoelectric focused shockwave machine<\/a><\/strong> we build.<\/p>\n\n\n\n<p><strong>There is no wear part to replace.<\/strong> No electrodes, no membranes, no projectiles. Output stays consistent across the life of the handpiece, which flattens the long-run cost curve \u2014 worth weighing against a low purchase price and years of consumable spend.<\/p>\n\n\n\n<p><strong>The small focal spot cuts both ways.<\/strong> A large lesion must be covered by moving the handpiece repeatedly. If most of your work is broad-area muscle relaxation, the precision you are paying for will never be used.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">05 The Buying Checklist: Specifications That Decide the Machine<\/h2>\n\n\n\n<p>Quotations arrive in mixed units, which makes comparison harder than it should be. Work through this list in order.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u0422\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438<\/th><th>What to look for<\/th><th>Why it matters<\/th><\/tr><\/thead><tbody><tr><td>Pressure \/ energy range<\/td><td>Stated in Bar or in mJ \u2014 know which<\/td><td>Determines whether deep structures are reachable<\/td><\/tr><tr><td>Frequency range<\/td><td>Hz, and whether it is continuously adjustable<\/td><td>Frequency and depth trade off against each other<\/td><\/tr><tr><td>\u0413\u043b\u0443\u0431\u0438\u043d\u0430 \u043f\u0440\u043e\u043d\u0438\u043a\u043d\u043e\u0432\u0435\u043d\u0438\u044f<\/td><td>mm, and whether it is fixed or selectable<\/td><td>The single clearest difference between radial and focused<\/td><\/tr><tr><td>Applicator \/ treatment head count<\/td><td>How many, and what each one is for<\/td><td>Decides how many service lines you can sell<\/td><\/tr><tr><td>Depth probes<\/td><td>Range in mm, number of steps<\/td><td>Lets one handpiece serve shallow and deep targets<\/td><\/tr><tr><td>Working modes<\/td><td>Preset count and whether they are body-part based<\/td><td>Shortens the operator learning curve<\/td><\/tr><tr><td>\u0418\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441<\/td><td>Screen size, and whether the handpiece has its own display<\/td><td>Affects treatment speed and operator fatigue<\/td><\/tr><tr><td>\u041d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435<\/td><td>Whether it accepts both 110 V and 220 V<\/td><td>Avoids a transformer on site<\/td><\/tr><tr><td>Packing size and weight<\/td><td>cm and kg, quoted separately<\/td><td>Freight cost and room-to-room mobility<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>Two entries deserve a note. On <strong>frequency<\/strong>, the relationship is counter-intuitive: lower settings generally reach deeper, while higher frequencies suit superficial work and trigger points. A machine that stops at 10 Hz is perfectly capable of deep work; one reaching 16 Hz simply gives more room at the superficial end. On <strong>voltage<\/strong>, dual-range input is not a marketing line \u2014 it is the difference between plugging in and sourcing a step-up transformer, which matters if you ship to more than one market.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">06 Handles, Heads and Depth Probes: Reading a Configuration<\/h2>\n\n\n\n<p>The configuration line of a quotation says more about capability than any single specification.<\/p>\n\n\n\n<p>A <strong>treatment head<\/strong> is the interchangeable applicator that touches the skin. Entry-level focused machines often ship with five to seven; the count maps to body regions, not power. A seven-head set usually covers elbow, knee, shoulder, hip, hand and wrist, lumbar region, and foot and ankle \u2014 plus, on machines built for men&#8217;s wellness, a dedicated applicator. The <strong><a href=\"https:\/\/www.konmison.com\/ru\/%d0%b0%d1%80%d1%82%d0%b8%d0%ba%d1%83%d0%bb-%d1%82%d0%be%d0%b2%d0%b0%d1%80%d0%b0\/portable-ed-shockwave-therapy-machine\/\">GN1002 portable unit<\/a><\/strong> is a good example: seven heads and ten working modes, preset by body region so the operator selects &#8220;shoulder&#8221; rather than dialling parameters from scratch.<\/p>\n\n\n\n<p>A <strong>depth probe<\/strong> \u2014 often a silicone or gel pad fitted over the applicator \u2014 shifts the focal distance, which is how one handpiece serves both a shallow wrist target and a deep gluteal one. On the GN1005 the pad set steps from 4 mm to 66 mm across several sizes, covering a range that would otherwise need two applicators.<\/p>\n\n\n\n<p>Two checks before you order. Ask whether the gel pads count as a consumable and at what interval \u2014 they are sacrificial parts and should be priced as such. Then confirm the head-to-mode mapping is automatic: on a preset machine the correct head is recommended for the selected body region, on a manual one the operator must remember the pairing \u2014 where most treatment errors start in a busy clinic.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">07 Two Service Lines on One Machine: Pain Relief and Men&#8217;s Wellness<\/h2>\n\n\n\n<p>A focused shockwave machine earns its place for a reason most supplier pages underplay: it carries two separate client groups without a second capital purchase.<\/p>\n\n\n\n<p>\u0421\u0430\u0439\u0442 <strong>pain and recovery line<\/strong> is the established one. Protocols are short \u2014 roughly ten to fifteen minutes per session, spaced a few days apart, several sessions to a course. No dedicated room or special power is needed, so an existing treatment bed and a free diary slot are enough to launch it.<\/p>\n\n\n\n<p>\u0421\u0430\u0439\u0442 <strong>men&#8217;s wellness line<\/strong> is newer and, in many markets, faster-growing. Focused shockwave energy is now a standard fixture in men&#8217;s health programmes, delivered with a dedicated applicator rather than the general-purpose heads. Two things make it commercially attractive: sessions are short, and clients return on a schedule \u2014 the repeatable booking pattern a menu built on one-off facials struggles to generate. Studios already running <strong><a href=\"https:\/\/www.konmison.com\/ru\/cet-ret-448khz-vs-rf-vs-ems-vs-cavitation\/\">body contouring technologies<\/a><\/strong> are the natural audience: the client relationship and the room are already in place.<\/p>\n\n\n\n<p>Focused shockwave is not the only physical modality aimed at pain. A <strong><a href=\"https:\/\/www.konmison.com\/ru\/%d0%b0%d1%80%d1%82%d0%b8%d0%ba%d1%83%d0%bb-%d1%82%d0%be%d0%b2%d0%b0%d1%80%d0%b0\/360-%d1%84%d0%b8%d0%b7%d0%b8%d1%87%d0%b5%d1%81%d0%ba%d0%b0%d1%8f-%d1%82%d0%b5%d1%80%d0%b0%d0%bf%d0%b8%d1%8f-%d0%bc%d0%b0%d0%b3%d0%bd%d0%b8%d1%82%d0%bd%d0%b0%d1%8f-%d1%81%d1%82%d0%b8%d0%bc%d1%83%d0%bb\/\">magnetic stimulation pain relief machine<\/a><\/strong> \u0438 <strong><a href=\"https:\/\/www.konmison.com\/ru\/%d0%b0%d1%80%d1%82%d0%b8%d0%ba%d1%83%d0%bb-%d1%82%d0%be%d0%b2%d0%b0%d1%80%d0%b0\/4-%d0%b2-1-%d0%bc%d0%b8%d0%ba%d1%80%d0%be-%d1%82%d0%be%d0%ba-%d0%bd%d0%b0%d0%b3%d1%80%d0%b5%d0%b2%d0%b0-%d0%be%d0%b1%d0%bb%d0%b5%d0%b3%d1%87%d0%b5%d0%bd%d0%b8%d1%8f-%d0%b1%d0%be%d0%bb%d0%b8-%d1%82\/\">micro-current heating pain relief machine<\/a><\/strong> cover adjacent ground with different mechanisms, and some clinics run more than one so a client who does not respond to the first has a second option on site.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">08 Comparing the Konmison Shockwave Range: GN1005, GN1002 and GN740<\/h2>\n\n\n\n<p>We build three shockwave machines, designed for different rooms rather than different price points.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th><\/th><th><strong>GN1005 \/ GN1005B<\/strong><\/th><th><strong>\u041e\u0431\u0449\u0438\u0435 \u043e\u0441\u043d\u043e\u0432\u044b \u043f\u0438\u0442\u0430\u043d\u0438\u044f 1002<\/strong><\/th><th><strong>GN740<\/strong><\/th><\/tr><\/thead><tbody><tr><td>\u041f\u043e\u0437\u0438\u0446\u0438\u043e\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435<\/td><td>Flagship focused station<\/td><td>Portable, men&#8217;s wellness in mind<\/td><td>Established focused workhorse<\/td><\/tr><tr><td>\u0422\u0435\u0445\u043d\u043e\u043b\u043e\u0433\u0438\u044f<\/td><td>Piezoelectric focused shockwave<\/td><td>\u0423\u0434\u0430\u0440\u043d\u043e-\u0432\u043e\u043b\u043d\u043e\u0432\u0430\u044f \u0442\u0435\u0440\u0430\u043f\u0438\u044f<\/td><td>Focus shockwaves<\/td><\/tr><tr><td>\u0420\u0443\u0447\u043a\u0438<\/td><td>1<\/td><td>1<\/td><td>1<\/td><\/tr><tr><td>\u041b\u0435\u0447\u0435\u0431\u043d\u044b\u0435 \u0433\u043e\u043b\u043e\u0432\u043a\u0438<\/td><td>8 (7 general + 1 dedicated)<\/td><td>7<\/td><td>7 silicone pads<\/td><\/tr><tr><td>Pressure \/ energy<\/td><td>1 \u2013 10 Bar<\/td><td>50 \u2013 200 mJ<\/td><td>1 \u2013 8 Bar<\/td><\/tr><tr><td>\u0427\u0430\u0441\u0442\u043e\u0442\u0430<\/td><td>1 \u2013 10 Hz<\/td><td>1 \u2013 16 Hz<\/td><td>1 \u2013 10 Hz<\/td><\/tr><tr><td>\u0413\u043b\u0443\u0431\u0438\u043d\u0430 \u043f\u0440\u043e\u043d\u0438\u043a\u043d\u043e\u0432\u0435\u043d\u0438\u044f<\/td><td>4 \u2013 66 mm, selectable<\/td><td>-<\/td><td>4 \u2013 66 mm<\/td><\/tr><tr><td>Working modes<\/td><td>Body-region presets<\/td><td>10 modes<\/td><td>7 body-region pads<\/td><\/tr><tr><td>\u0418\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441<\/td><td>15&#8243; main screen + 1.8&#8243; handle screen<\/td><td>\u0423\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u0435 \u0441 \u043f\u043e\u043c\u043e\u0449\u044c\u044e \u0441\u0435\u043d\u0441\u043e\u0440\u043d\u043e\u0433\u043e \u044d\u043a\u0440\u0430\u043d\u0430<\/td><td>15&#8243; screen<\/td><\/tr><tr><td>\u041d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435<\/td><td>AC 110 \u2013 220 V \u00b115%, 50\/60 Hz<\/td><td>-<\/td><td>AC 100 \u2013 240 V, 50\/60 Hz<\/td><\/tr><tr><td>\u0420\u0430\u0437\u043c\u0435\u0440 \u0438\u0437\u0434\u0435\u043b\u0438\u044f<\/td><td>51 \u00d7 45 \u00d7 112 cm<\/td><td>-<\/td><td>-<\/td><\/tr><tr><td>Packing size \/ weight<\/td><td>61 \u00d7 51 \u00d7 120 cm \/ 43 kg<\/td><td>55 \u00d7 48 \u00d7 31 cm \/ 6.5 kg<\/td><td>53 \u00d7 50 \u00d7 60 cm \/ 23 kg<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p><em>\u2014 = Not published for this model. All values shown are factory specifications; custom configurations are available on request.<\/em><\/p>\n\n\n\n<p><strong>Choose GN1005<\/strong> if the machine will anchor a fixed treatment room and you want the tightest focal precision plus the widest depth range. It is the only one of the three built on a piezoelectric array, and the dual-screen interface is the fastest to operate in a busy diary.<\/p>\n\n\n\n<p><strong>Choose GN1002<\/strong> if the equipment needs to travel \u2014 a small room, a trolley, several sites. At 6.5 kg packed it goes anywhere, and the ten region-based modes make it the quickest to hand to a new operator. Its 16 Hz ceiling gives the most control at the superficial end.<\/p>\n\n\n\n<p><strong>Choose GN740<\/strong> if you are adding focused shockwave to an existing physiotherapy or massage business and want a proven, self-contained unit in an aluminium case. The <strong><a href=\"https:\/\/www.konmison.com\/ru\/%d0%b0%d1%80%d1%82%d0%b8%d0%ba%d1%83%d0%bb-%d1%82%d0%be%d0%b2%d0%b0%d1%80%d0%b0\/7-%d0%b2-1-%d0%b2%d1%8b%d1%81%d0%be%d0%ba%d0%b0%d1%8f-%d1%8d%d0%bd%d0%b5%d1%80%d0%b3%d0%b8%d1%8f-%d0%b1%d0%be%d0%bb%d0%b5%d0%b7%d0%bd%d0%b5%d0%bd%d0%bd%d0%b0%d1%8f-%d0%be%d0%b1%d0%bb%d0%b5%d0%b3%d1%87\/\">7 in 1 focus shockwaves pain relief machine<\/a><\/strong> has been in our range longest and remains the most straightforward to service.<\/p>\n\n\n\n<p>For rooms that move between modalities rather than specialising in shockwave, the wider <strong><a href=\"https:\/\/www.konmison.com\/ru\/%d0%ba%d0%be%d1%81%d0%bc%d0%b5%d1%82%d0%b8%d1%87%d0%b5%d1%81%d0%ba%d0%b8%d0%b5-%d0%bc%d0%b0%d1%88%d0%b8%d0%bd%d1%8b\/%d0%bf%d0%be%d1%80%d1%82%d0%b0%d1%82%d0%b8%d0%b2%d0%bd%d0%be%d0%b5-%d1%83%d1%81%d1%82%d1%80%d0%be%d0%b9%d1%81%d1%82%d0%b2%d0%be\/\">portable handheld range<\/a><\/strong> covers complementary equipment for the same trolley and the same operator skill set.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/www.konmison.com\/wp-content\/uploads\/2026\/09\/konmison-shockwave-lineup-gn1005-gn1002-gn740-1200x675-1.png\" alt=\"GN1005, GN1002 and GN740 shockwave therapy machines side by side\" class=\"wp-image-90093\" srcset=\"https:\/\/www.konmison.com\/wp-content\/uploads\/2026\/09\/konmison-shockwave-lineup-gn1005-gn1002-gn740-1200x675-1.png 1200w, https:\/\/www.konmison.com\/wp-content\/uploads\/2026\/09\/konmison-shockwave-lineup-gn1005-gn1002-gn740-1200x675-1-18x10.png 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">Three machines, three published specification sheets.<\/figcaption><\/figure><\/div>\n\n\n<h2 class=\"wp-block-heading\">09 Setting Up the Service: Room, Consumables and Operator Training<\/h2>\n\n\n\n<p>Shockwave is one of the least demanding modalities to add to an existing room.<\/p>\n\n\n\n<p><strong>The room.<\/strong> No shielding, no plumbing, no dedicated power supply. A treatment bed, a chair for the operator and about a square metre of free floor is enough. Mobility is worth deciding up front: a 6.5 kg portable behaves very differently from a 43 kg floor-standing unit.<\/p>\n\n\n\n<p><strong>The consumables.<\/strong> A session needs a coupling medium \u2014 gel applied to the skin so the wave crosses into tissue instead of reflecting off the air gap. This is the same category used in ultrasound and RF work, so most clinics already stock it. Gel pads on machines that use depth probes are the second item: inspect them for cracks and replace when damaged, because a compromised pad changes the focal distance.<\/p>\n\n\n\n<p><strong>Operator training.<\/strong> The skill is not in setting parameters \u2014 preset modes handle most of that. It is in locating the target: palpating the area to find the tender point, then moving the handpiece in a slow circular or linear motion without dwelling over one spot. Suppliers who treat training as a one-hour handover are the ones whose clients complain.<\/p>\n\n\n\n<p><strong>The surrounding paperwork.<\/strong> A new service line is a small business project, not only an equipment purchase. Our guides on <strong><a href=\"https:\/\/www.konmison.com\/ru\/%d0%ba%d0%b0%d0%ba-%d0%be%d1%82%d0%ba%d1%80%d1%8b%d1%82%d1%8c-%d0%bc%d0%b5%d0%b4%d0%b8%d1%86%d0%b8%d0%bd%d1%81%d0%ba%d0%b8%d0%b9-%d1%81%d0%bf%d0%b0-%d1%86%d0%b5%d0%bd%d1%82%d1%80\/\">\u043a\u0430\u043a \u043e\u0442\u043a\u0440\u044b\u0442\u044c \u043c\u0435\u0434\u0438\u0446\u0438\u043d\u0441\u043a\u0438\u0439 \u0441\u043f\u0430-\u0446\u0435\u043d\u0442\u0440<\/a><\/strong>, the <strong><a href=\"https:\/\/www.konmison.com\/ru\/medical-aesthetics-business-plan-guide\/\">medical aesthetics business plan<\/a><\/strong> \u0438 <strong><a href=\"https:\/\/www.konmison.com\/ru\/beauty-salon-business-plan-guide\/\">\u0431\u0438\u0437\u043d\u0435\u0441-\u043f\u043b\u0430\u043d \u0441\u0430\u043b\u043e\u043d\u0430 \u043a\u0440\u0430\u0441\u043e\u0442\u044b<\/a><\/strong> cover the structure, while the <strong><a href=\"https:\/\/www.konmison.com\/ru\/%d1%81%d0%bf%d0%b8%d1%81%d0%be%d0%ba-%d1%80%d0%b0%d1%81%d1%85%d0%be%d0%b4%d0%bd%d1%8b%d1%85-%d0%bc%d0%b0%d1%82%d0%b5%d1%80%d0%b8%d0%b0%d0%bb%d0%be%d0%b2-%d0%b8-%d0%be%d0%b1%d0%be%d1%80%d1%83%d0%b4\/\">\u0441\u043f\u0438\u0441\u043e\u043a \u0440\u0430\u0441\u0445\u043e\u0434\u043d\u044b\u0445 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u043e\u0432 \u0438 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f \u0434\u043b\u044f \u044d\u0441\u0442\u0435\u0442\u0438\u0441\u0442\u0430<\/a><\/strong> \u0438 <strong><a href=\"https:\/\/www.konmison.com\/ru\/%d1%81%d0%bf%d0%b8%d1%81%d0%be%d0%ba-%d1%80%d0%b0%d1%81%d1%85%d0%be%d0%b4%d0%bd%d1%8b%d1%85-%d0%bc%d0%b0%d1%82%d0%b5%d1%80%d0%b8%d0%b0%d0%bb%d0%be%d0%b2-%d0%b4%d0%bb%d1%8f-%d1%8d%d1%81%d1%82%d0%b5\/\">\u0421\u043f\u0438\u0441\u043e\u043a \u0440\u0430\u0441\u0445\u043e\u0434\u043d\u044b\u0445 \u043c\u0430\u0442\u0435\u0440\u0438\u0430\u043b\u043e\u0432 \u0434\u043b\u044f \u044d\u0441\u0442\u0435\u0442\u0438\u0441\u0442\u0430<\/a><\/strong> are the practical counterparts. If you are launching in a new market, <strong><a href=\"https:\/\/www.konmison.com\/ru\/how-to-start-an-aesthetics-business\/\">\u043a\u0430\u043a \u043d\u0430\u0447\u0430\u0442\u044c \u0431\u0438\u0437\u043d\u0435\u0441 \u0432 \u0441\u0444\u0435\u0440\u0435 \u044d\u0441\u0442\u0435\u0442\u0438\u043a\u0438<\/a><\/strong> sets out the sequence, and the <strong><a href=\"https:\/\/www.konmison.com\/ru\/%d0%ba%d0%be%d1%81%d0%bc%d0%b5%d1%82%d0%b8%d1%87%d0%b5%d1%81%d0%ba%d0%b8%d0%b5-%d0%bc%d0%b0%d1%88%d0%b8%d0%bd%d1%8b\/\">beauty machines catalogue<\/a><\/strong> is where the full equipment range sits.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">10 Frequently Asked Questions<\/h2>\n\n\n\n<p><strong>Is a focused shockwave machine better than a radial one?<\/strong><\/p>\n\n\n\n<p>Neither is better in the abstract; they solve different problems. Radial covers a wide, shallow area and tolerates imprecise positioning, which suits general muscle work. Focused deposits energy at a defined depth \u2014 what you need for chronic tendon attachments, small deep lesions and men&#8217;s wellness protocols. Many established clinics eventually run one of each.<\/p>\n\n\n\n<p><strong>How deep can a shockwave machine work?<\/strong><\/p>\n\n\n\n<p>It depends on the type, not the brand. Radial waves are typically quoted at roughly 1.3 to 3.8 cm of effective penetration, because the energy diverges and decays quickly. Focused machines reach considerably deeper, with exact depth set by the applicator or depth probe \u2014 GN1005 and GN740 both adjust across 4 mm to 66 mm using different pads.<\/p>\n\n\n\n<p><strong>What does piezoelectric mean, and does it matter?<\/strong><\/p>\n\n\n\n<p>It describes how the wave is generated. An array of ceramic crystals deforms under voltage and produces the pulse inside a water-filled applicator, with no compressor, projectile or acoustic lens. It delivers the smallest focal volume of the three mainstream designs and removes the wear parts, so output stays consistent over a long service life. Whether that matters depends on your client mix: if most of your work is broad-area relaxation, a pneumatic or electromagnetic machine will do the job for less.<\/p>\n\n\n\n<p><strong>What room and licensing setup does it need?<\/strong><\/p>\n\n\n\n<p>Room requirements are modest: a clean treatment space, standard mains power and a coupling gel. Licensing and permit rules for the service itself vary by market, so confirm them locally before you advertise.<\/p>\n\n\n\n<p><strong>How long is a session, and how many will a client need?<\/strong><\/p>\n\n\n\n<p>Ten to fifteen minutes typically, with intervals of a few days and several sessions forming a course. Protocols are usually reassessed after the first course rather than committing a client to a fixed schedule.<\/p>\n\n\n\n<p><strong>Is it comfortable for the client?<\/strong><\/p>\n\n\n\n<p>Piezoelectric designs are generally reported as the most comfortable, because the wide aperture keeps energy density at the skin low; radial concentrates more at the surface. Operators adjust by lowering intensity and raising frequency if a setting feels too strong, and reversing that if too mild.<\/p>\n\n\n\n<p><strong>Can one machine serve both pain relief and men&#8217;s wellness?<\/strong><\/p>\n\n\n\n<p>Yes, and that is the commercial argument for a focused machine. The general-purpose heads cover the pain and recovery work; a dedicated applicator handles the men&#8217;s wellness protocol. The GN1005 ships with eight heads for exactly this reason, and portable units such as the GN1002 build the same range into a smaller footprint.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">11 Conclusion<\/h2>\n\n\n\n<p>The decision is not about brand, price tier or screen size. Two questions settle it, in order: does the energy converge on a focal point, or spread in a fan? And is the wave pneumatic, electromagnetic or piezoelectric?<\/p>\n\n\n\n<p>Once those are settled, the rest of the spec sheet reads as consequences: focal machines reach small deep targets, radial machines cover wide shallow areas cheaply, and piezoelectric arrays add precision and remove wear parts at a higher build cost. Head count, depth probes, portability and voltage all follow from how the room will be used.<\/p>\n\n\n\n<p>Match those characteristics to the clients you actually have \u2014 not the ones you hope to have \u2014 and the quotation will tell you whether the machine belongs in your clinic.<\/p>\n\n\n\n<script type=\"application\/ld+json\">{\n    \"@context\": \"https:\\\/\\\/schema.org\",\n    \"@graph\": [\n        {\n            \"@type\": \"Organization\",\n            \"@id\": \"https:\\\/\\\/www.konmison.com\\\/#organization\",\n            \"name\": \"Konmison\",\n            \"alternateName\": \"Guangzhou Konmison Technology Co., Ltd.\",\n            \"url\": \"https:\\\/\\\/www.konmison.com\",\n            \"logo\": \"https:\\\/\\\/www.konmison.com\\\/wp-content\\\/uploads\\\/konmison-logo.png\",\n            \"contactPoint\": {\n                \"@type\": \"ContactPoint\",\n                \"contactType\": \"sales\",\n                \"email\": \"export01@konmison.net\",\n                \"telephone\": \"+86-13247551793\",\n                \"availableLanguage\": [\n                    \"English\",\n                    \"Chinese\"\n                ]\n            }\n        },\n        {\n            \"@type\": \"Article\",\n            \"@id\": \"https:\\\/\\\/www.konmison.com\\\/shockwave-therapy-machine-focused-vs-radial\\\/#article\",\n            \"headline\": \"Shockwave Therapy Machine Buyer's Guide: Focused vs Radial\",\n            \"description\": \"Compare focused, radial and piezoelectric shockwave therapy machines before you buy: energy types, penetration depth, treatment heads and clinic setup.\",\n            \"inLanguage\": \"en\",\n            \"mainEntityOfPage\": {\n                \"@type\": \"WebPage\",\n                \"@id\": \"https:\\\/\\\/www.konmison.com\\\/shockwave-therapy-machine-focused-vs-radial\\\/\"\n            },\n            \"publisher\": {\n                \"@id\": \"https:\\\/\\\/www.konmison.com\\\/#organization\"\n            },\n            \"about\": [\n                {\n                    \"@type\": \"Thing\",\n                    \"name\": \"Shockwave therapy machine\"\n                },\n                {\n                    \"@type\": \"Thing\",\n                    \"name\": \"Focused shockwave therapy\"\n                },\n                {\n                    \"@type\": \"Thing\",\n                    \"name\": \"Radial shockwave therapy\"\n                },\n                {\n                    \"@type\": \"Thing\",\n                    \"name\": \"Piezoelectric shockwave applicator\"\n                }\n            ],\n            \"articleSection\": \"Buyer Guide\"\n        },\n        {\n            \"@type\": \"FAQPage\",\n            \"@id\": \"https:\\\/\\\/www.konmison.com\\\/shockwave-therapy-machine-focused-vs-radial\\\/#faq\",\n            \"mainEntity\": [\n                {\n                    \"@type\": \"Question\",\n                    \"name\": \"Is a focused shockwave machine better than a radial one?\",\n                    \"acceptedAnswer\": {\n                        \"@type\": \"Answer\",\n                        \"text\": \"Neither is better in the abstract; they solve different problems. Radial covers a wide, shallow area and tolerates imprecise positioning, which suits general muscle work. Focused deposits energy at a defined depth \\u2014 what you need for chronic tendon attachments, small deep lesions and men's wellness protocols. Many established clinics eventually run one of each.\"\n                    }\n                },\n                {\n                    \"@type\": \"Question\",\n                    \"name\": \"How deep can a shockwave machine work?\",\n                    \"acceptedAnswer\": {\n                        \"@type\": \"Answer\",\n                        \"text\": \"It depends on the type, not the brand. Radial waves are typically quoted at roughly 1.3 to 3.8 cm of effective penetration, because the energy diverges and decays quickly. Focused machines reach considerably deeper, with exact depth set by the applicator or depth probe \\u2014 GN1005 and GN740 both adjust across 4 mm to 66 mm using different pads.\"\n                    }\n                },\n                {\n                    \"@type\": \"Question\",\n                    \"name\": \"What does piezoelectric mean, and does it matter?\",\n                    \"acceptedAnswer\": {\n                        \"@type\": \"Answer\",\n                        \"text\": \"It describes how the wave is generated. An array of ceramic crystals deforms under voltage and produces the pulse inside a water-filled applicator, with no compressor, projectile or acoustic lens. It delivers the smallest focal volume of the three mainstream designs and removes the wear parts, so output stays consistent over a long service life. Whether that matters depends on your client mix: if most of your work is broad-area relaxation, a pneumatic or electromagnetic machine will do the job for less.\"\n                    }\n                },\n                {\n                    \"@type\": \"Question\",\n                    \"name\": \"What room and licensing setup does it need?\",\n                    \"acceptedAnswer\": {\n                        \"@type\": \"Answer\",\n                        \"text\": \"Room requirements are modest: a clean treatment space, standard mains power and a coupling gel. Licensing and permit rules for the service itself vary by market, so confirm them locally before you advertise.\"\n                    }\n                },\n                {\n                    \"@type\": \"Question\",\n                    \"name\": \"How long is a session, and how many will a client need?\",\n                    \"acceptedAnswer\": {\n                        \"@type\": \"Answer\",\n                        \"text\": \"Ten to fifteen minutes typically, with intervals of a few days and several sessions forming a course. Protocols are usually reassessed after the first course rather than committing a client to a fixed schedule.\"\n                    }\n                },\n                {\n                    \"@type\": \"Question\",\n                    \"name\": \"Is it comfortable for the client?\",\n                    \"acceptedAnswer\": {\n                        \"@type\": \"Answer\",\n                        \"text\": \"Piezoelectric designs are generally reported as the most comfortable, because the wide aperture keeps energy density at the skin low; radial concentrates more at the surface. Operators adjust by lowering intensity and raising frequency if a setting feels too strong, and reversing that if too mild.\"\n                    }\n                },\n                {\n                    \"@type\": \"Question\",\n                    \"name\": \"Can one machine serve both pain relief and men's wellness?\",\n                    \"acceptedAnswer\": {\n                        \"@type\": \"Answer\",\n                        \"text\": \"Yes, and that is the commercial argument for a focused machine. The general-purpose heads cover the pain and recovery work; a dedicated applicator handles the men's wellness protocol. The GN1005 ships with eight heads for exactly this reason, and portable units such as the GN1002 build the same range into a smaller footprint.\"\n                    }\n                }\n            ]\n        }\n    ]\n}<\/script>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>A shockwave therapy machine makes an unusual promise to a clinic: no needle, no per-session consumable, no downtime, and a slot that runs ten to fifteen minutes. That is why so many salons, physiotherapy rooms and men&#8217;s wellness studios added one over the past three years \u2014 and why a good number bought the wrong [&hellip;]<\/p>","protected":false},"author":3,"featured_media":90094,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_seopress_robots_primary_cat":"none","_seopress_titles_title":"Shockwave Therapy Machine Buyer's Guide: Focused vs Radial","_seopress_titles_desc":"Compare focused, radial and piezoelectric shockwave therapy machines before you buy: energy types, penetration depth, treatment heads and clinic setup.","_seopress_robots_index":"","footnotes":""},"categories":[56],"tags":[],"class_list":["post-90088","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blogs"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.konmison.com\/ru\/wp-json\/wp\/v2\/posts\/90088","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.konmison.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.konmison.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.konmison.com\/ru\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.konmison.com\/ru\/wp-json\/wp\/v2\/comments?post=90088"}],"version-history":[{"count":1,"href":"https:\/\/www.konmison.com\/ru\/wp-json\/wp\/v2\/posts\/90088\/revisions"}],"predecessor-version":[{"id":90095,"href":"https:\/\/www.konmison.com\/ru\/wp-json\/wp\/v2\/posts\/90088\/revisions\/90095"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.konmison.com\/ru\/wp-json\/wp\/v2\/media\/90094"}],"wp:attachment":[{"href":"https:\/\/www.konmison.com\/ru\/wp-json\/wp\/v2\/media?parent=90088"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.konmison.com\/ru\/wp-json\/wp\/v2\/categories?post=90088"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.konmison.com\/ru\/wp-json\/wp\/v2\/tags?post=90088"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}